California Prop 65 warning for Nickel Carbonate: wash hands after internal servicing.
Incorrect 115V/230V switch setting risks severe overvoltage damage.
Root Failure Mechanism: Front Rotary Volume Encoder DegradationClick to spotlight part ↑
01 // Trigger ConditionFrequent manual adjustment of the Master Volume/Multi knob.
02 // Degradation PhysicsMechanical wiper oxidation, contact bounce, or wear of internal detent mechanism.
03 // Lockout / ImpactErratic volume jumps, unresponsive volume adjustment, or difficulty navigating menus via the encoder.
Before Ordering Parts: Normal Operation vs. True Fault
False-Alarm Check — Audible fan noise persists even when unit is put in standby via remote.: The cooling fan is designed to run continuously even in soft standby mode to ensure adequate cooling for internal components, as confirmed by owner reports and design topology. (True fault when: If the fan noise becomes excessively loud, grinding, or stops entirely, it may indicate a fan bearing failure or obstruction.)
False-Alarm Check — Center/surround trim levels (CV, SRV, SLV, SWV) reset after power-off.: The unit's MCU memory for certain trim settings is volatile and does not retain these specific adjustments when the unit is fully powered down (not just standby). (True fault when: If other settings (e.g., input selection, tuner presets) also reset, it could indicate a broader power loss or memory corruption issue.)