Sony STRDH190: PROTECT Display & Auto Shutoff
What this means: Display flashes 'PROTECT'; unit powers off after a few seconds. This indicates the internal protection circuit has detected a fault (e.g., short circuit, DC offset, overheating).
60-Second Verification Check
Unplug AC for 30 minutes. Disconnect ALL speakers and inputs. Power on the bare unit. If 'PROTECT' clears, the fault is external (speakers/wiring/source). If 'PROTECT' persists, the internal amplifier/Main PCB (A2194643A) has failed.
Verified Replacement Parts
Output Power Transistors (Pair)
Direct semiconductor replacement. Requires careful matching and installation by a qualified technician. Inspect emitter resistors when replacing shorted outputs.
Main Mounted PC Board
Direct OEM replacement part for the STR-DH190. Ensures full compatibility and safety.
Why This Happens & Safety Warnings
- UNLEADED SOLDER (LF) warning: Iron temp must stay ~350°C without prolonged dwell to prevent copper foil peeling.
- AC chassis leakage test: Must verify <= 0.5 mA (500 µA) AC chassis leakage before returning the unit after repair.
What triggers it: Improper speaker wire termination (stray strands) or connecting speakers with impedance below 6 Ω (A/B) / 12 Ω (A+B).
What wears out inside: Stray copper strands create a short circuit, or low impedance loads cause excessive current draw, exceeding the amplifier's safe operating area. The MICOM-controlled protection circuit detects this fault.
Symptom on machine: Unit immediately shuts down, displaying 'PROTECT' on the front panel, preventing audio output and requiring user intervention to reset.
What triggers it: Sustained high-power output (e.g., into 4 Ω loads) or operation in a confined, poorly ventilated environment.
What wears out inside: The linear power transformer generates significant heat under heavy load. Inadequate cooling leads to thermal runaway, degrading the winding insulation and potentially causing an internal thermal fuse to open or windings to short/open.
Symptom on machine: Unit fails to power on, or powers on briefly (LED lights up for ~8 seconds) then shuts down, often accompanied by a burnt varnish odor. Complete loss of function.
Cross-Compatible Platforms: Shares Sony STR-DH series PROTECT reset/diagnostics and CLEARING/CLEARED* factory reset flow across sibling receivers (STR-DH590/STR-DH790)