01 // Observed Condition

Thermostat loses power or restarts unexpectedly, often coinciding with HVAC system operation.

02 // Non-Invasive Meter / Bench Verification

Verify stable 24VAC at backplate R–C terminals. Confirm PEK wiring matches app instructions. Check HVAC transformer capacity and wiring connections.

Platform / OEM Cross-Reference: Family user guide cites FCC ID WR955470766937 / IC 7981A-55470766937.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
Generic 24VAC… Power Extender Kit (PEK)
Must be compatible with 24VAC HVAC systems and provide the necessary C-wire conversion functionality. OEM part is designed for exact compatibility.
Check Live Stock
Part 2
universal aftermarket part
Isolated Match
Generic 24VAC coil… 24V Isolation Relay
Required by datasheet for self-powered accessories. Must be a standard 24VAC isolation relay suitable for HVAC control circuits.
Check Live Stock
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified learning multi stage smart thermostats replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALFAULT IMPLICATED
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:CopperLithium IonLithium-IonTRIAC

Failure Physics & Causal Isolation

Root Failure Mechanism: 24VAC Power Brownout / RebootingClick to spotlight part ↑

01 // Trigger ConditionHVAC system (e.g., compressor, fan) cycles on, or thermostat's Wi-Fi/radar activity increases power draw.
02 // Degradation PhysicsThe thermostat's 2.0W peak power draw exceeds the margin of an aged or undersized 24VAC HVAC transformer, or there is a loose splice in the PEK wiring, leading to a voltage sag below operational thresholds.
03 // Lockout / ImpactThermostat display turns off, reboots, or operates erratically, leading to loss of HVAC control or scheduling.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Mobile alert of rapid indoor cooling: This is a built-in freeze/damage protection notification (e.g., 'Sudden Temperature Drop') designed to alert users to potential issues like an open door/window or an HVAC outage, not necessarily a thermostat fault. (True fault when: If the notification persists despite checking for open windows/doors and the HVAC system is confirmed to be operating correctly, it could indicate a sensor malfunction or a logic error.)
False-Alarm Check — Displayed temperature or humidity differs slightly from other sensors: The thermostat has specified tolerances of ±1°F (±0.5°C) for temperature and ±5% RH for humidity. Minor variations within these tolerances are normal. (True fault when: If the difference consistently exceeds the specified tolerances, or if the readings are erratic, it may indicate a sensor issue or environmental interference (e.g., drafts).)