MULTI-BRAND ODM 12: F7 / L8 / P4 (IPM Module or Compressor Exhaust Over-Temperature Lockout)
⚡ Bench Triage & Meter Telemetry
122°F50°C
01 // Observed Condition
Safety shutdown triggered when the Intelligent Power Module (IPM) internal thermal sensor or compressor discharge thermistor exceeds safe thermal operating limits.
02 // Non-Invasive Meter / Bench Verification
First verify that outdoor ambient temperature is below 122°F (50°C), the outdoor condenser coil has at least 24 inches of clearance and clean fins, and the outdoor axial fan is spinning. If airflow is normal, a qualified technician must discharge the capacitors (10-minute wait) and inspect the thermal interface paste between the IPM and aluminum heatsink for chalky dry-out.
Platform / OEM Cross-Reference: Apply general Midea/Gree/AUX error code matrices to diagnostic troubleshooting flows, as the microcontrollers utilize overlapping logic structures.