FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: OL17003-CCT-CA-1 TIER 4 LICENSED / SEALED

OREiN OL17003-CCT-CA-1: Light settings bypass or change unexpectedly; fan mode changes unintentionally

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

The main 3CCT light or 2200K nightlight changes color temperature or mode without user input, or the fan mode (Auto/Manual) switches unexpectedly.

02 // Non-Invasive Meter / Bench Verification

Confirm fan and light are wired on separate switch legs/circuits and that no wall dimmer or timer switch is installed.

Platform / OEM Cross-Reference: OL17003-CCT-CA-1 shares core OL17003/OL003 platform specs (160 CFM, 1.0 Sone, 40W, 1500 lm, 11.81" x 11.02" cutout) with OL17003-CCT-US-1 and OL17003-CCT-US-1-WM.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
Replacement Light Grille… Replacement Light Grille / LED Module
Proprietary mounting springs, 3CCT/2200K LED PCB & plug.
Check Live Stock
Part 2
oem replacement part
Isolated Match
Replacement Brushless… Replacement Brushless Motor / Sensor PCB
Integrated housing/fan power module.
$169.99 est. full-unit street ($189.99–$249.99 OEM listings)
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified bathroom humidity sensing exhaust fans replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALFAULT IMPLICATED
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICFAULT IMPLICATED
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:CopperPTC

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Circuit breaker must be OFF before any cleaning or inspection.
  • Caution required when lowering the light grille due to short internal LED cover leads.

Root Failure Mechanism: Erratic LED / Fan Mode Behavior due to Incompatible Controls or WiringClick to spotlight part ↑

01 // Trigger ConditionInstallation with incompatible electrical controls (dimmers, timers, solid-state speed controls) or shared fan/light wiring on a single switch.
02 // Degradation PhysicsIncompatible electrical signals or power fluctuations corrupt the internal power-cycle state machine logic, leading to unintended mode transitions or LED CCT changes.
03 // Lockout / ImpactUnpredictable fan operation, light color temperature changes, or inability to select desired mode (Auto/Manual).

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Fan runs continuously for extended periods (hours/days) in Auto mode.: The fan's humidity sensor triggers at 60% RH and remains active as long as ambient indoor humidity is at or above this threshold. In homes with consistently high ambient humidity, continuous operation is normal. (True fault when: If a hygrometer confirms ambient RH is consistently below 60% and the fan still runs continuously in Auto mode, it may indicate a sensor malfunction.)

Other OREiN OL17003-CCT-CA-1 Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...