Tech Drive TD-BF-10H: Fan Runs Continuously / Won't Shut Off
What this means: Fan stays ON even after visible steam dissipates.
60-Second Verification Check
Check LED color (Red = continuous Manual; Green = Auto); measure room RH with hygrometer (<60%?); power-cycle switch for 10–15 sec and clean sensor.
Verified Replacement Parts
Replacement Humidity Sensor / Grille
Housing-specific clip geometry and sensor harness require an OEM-specific part.
Why This Happens & Safety Warnings
- Power OFF; prohibit direct water contact on motor/electronics; dry fully before restoring power (during cleaning).
- Disconnect breaker and never spray water directly into motor or sensor electronics (during cleaning).
What triggers it: High bathroom humidity, seasonal ambient conditions, or user selection of manual mode.
What wears out inside: Lint/aerosol fouling on sensor element skews RH readings, or high seasonal indoor RH keeps fan running continuously, or accidental Red Manual mode latch.
Symptom on machine: Fan runs continuously, leading to increased energy consumption, nuisance noise, and potential accelerated motor wear.
Cross-Compatible Platforms: TD-BF-10 (B08CSHM2QR) cleaning, troubleshooting, and plug-in motor installation procedures.