Vine See OEM Spec: Heat or Cool Runs Continuously / Won't Shut Off

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

HVAC stays energized even when thermostat is set to OFF.

02 // Non-Invasive Meter / Bench Verification

Pull front faceplate off the wall backplate: if HVAC stops immediately, the thermostat relay is stuck; if HVAC keeps running, the fault is in the wall wiring or furnace board.

Platform / OEM Cross-Reference: Vine Connected 24VAC smart thermostat family traits (Vine Smart app, 2.4 GHz Wi-Fi, Alexa/Google support, 24VAC Class 2 control) apply at CONFIRMED_BRAND_FAMILY level.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
Subminiature 5V/12V/24V… PCB Switching Relays
Requires exact match of coil voltage, contact rating, and PCB footprint. Professional electronics repair only.
Generic: $1–$4 each
Part 2
routine consumable
Isolated Match
ATO/ATC 3A (violet) or 5A… Furnace Control-Board Fuse
Standard automotive-style blade fuse for 24VAC HVAC control boards. Match amperage and voltage rating.
Generic: $1–$5
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified wifi smart thermostats replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALFAULT IMPLICATED
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORNOMINAL ON SKU
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSBRASSNTCTRIAC

Failure Physics & Causal Isolation

Root Failure Mechanism: Output Relay Contact Welding / StickingClick to spotlight part ↑

01 // Trigger ConditionRepeated switching of inductive HVAC loads (e.g., AC condenser contactor coils) over many cycles.
02 // Degradation PhysicsInductive arcing across relay contacts causes pitting and eventual welding of the contacts in a closed position.
03 // Lockout / ImpactHVAC system (heating, cooling, or fan) runs continuously and cannot be turned off by the thermostat.

Root Failure Mechanism: Installation Short Blowing Control Fuse / Output Stage DamageClick to spotlight part ↑

01 // Trigger ConditionUser attempts to wire the thermostat while 24VAC HVAC power is still live.
02 // Degradation PhysicsAccidental short circuit between R and C/G terminals, causing an overcurrent event.
03 // Lockout / ImpactBlowing the furnace control-board 3A–5A fuse (resulting in no power to thermostat) or damaging the thermostat's internal output switching stage (e.g., stuck relay).

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Compressor Delay Wait Indicator: This is a normal 3–5 minute built-in compressor protection delay to equalize refrigerant head pressure and prevent damage to the HVAC system. (True fault when: Only if the delay exceeds 10 minutes, which could indicate a thermostat or HVAC system fault.)