FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: VH1796 TIER 4 LICENSED / SEALED

VIVOHOME VH1796: Dead unit on wall switch or humidity spike (no power)

⚡ Bench Triage & Meter Telemetry
110–120V

01 // Observed Condition

The fan does not activate when the wall switch is engaged or when a humidity spike is detected.

02 // Non-Invasive Meter / Bench Verification

Verify 110–120V AC at ceiling supply leads using a multimeter. Inspect wiring diagram connections for proper installation. Check circuit breaker.

Platform / OEM Cross-Reference: Shares factory manual with VH1797 (0.1–1.0–1.5 sone multi-speed variant)

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
VH1796 Complete Replacement Fan Assembly (VH1796)
Direct replacement unit for the VIVOHOME VH1796 model.
~$59.49
Part 2
universal aftermarket part
Isolated Match
4-in UL 181 Class 0/1… 4-Inch Flexible Aluminum Duct
Standard 4-inch diameter ducting compatible with the fan's exhaust collar. Insulated versions are recommended to prevent condensation.
$12–$25 (Generic)
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified bathroom humidity exhaust fans replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICFAULT IMPLICATED
MOD_06 // OPTICAL & SENSORNOMINAL ON SKU
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSCopperPTC

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Disconnect Power Before Servicing: Manual explicitly states to switch off the circuit breaker before any cleaning or inspection, and never service live ceiling wiring.
  • No Water-Seepage Locations: Manual warns against installation where roof/plumbing seepage can drip onto the motor housing or electronics.

Root Failure Mechanism: EC Driver PCB Surge / Moisture FailureClick to spotlight part ↑

01 // Trigger ConditionLine voltage transients (spikes/sags) or prolonged exposure to high humidity/condensation.
02 // Degradation PhysicsDegradation of electrolytic capacitors, switching semiconductors, or corrosion/ionic migration on the PCB due to moisture ingress (if unpotted).
03 // Lockout / ImpactFan fails to start, operates intermittently, or ceases function entirely.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Fan runs longer or shorter than expected based on user's desired humidity level.: The VIVOHOME VH1796 features a factory-preset, non-adjustable humidity sensor. Its trigger points are fixed and cannot be changed by the user. This is a design characteristic, not a malfunction. (True fault when: If the fan never triggers despite high humidity, or runs continuously even in dry conditions, it may indicate a sensor malfunction or fouling.)

Other VIVOHOME VH1796 Diagnostic Sheets