Bar Maid A-200: Cord-integrated GFCI module trips repeatedly or motor fails to power on
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
Ground-fault leakage current detected across wet plug/switch contacts or internal motor winding short caused by water ingress past the column water line.
02 // Non-Invasive Meter / Bench Verification
Inspect whether the sink was overfilled past the column marker or if the unit tipped into the water. Allow external plug and switch housing to dry completely in ambient air, then press the GFCI RESET button on a known-good 115V outlet.
Platform / OEM Cross-Reference: Rotary scrub brushes (BRS-917, BRS-920, BRS-922, BRS-1722) use universal Bar Maid spindle mounts shared between Upright (A-200) and Submersible (SS-100) glass washer models.