HARDWARE SYMPTOM MODEL: AA-SUB TIER 4 LICENSED / SEALED

Bar Maid AA-SUB: GFCI plug or wall outlet trips immediately

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Ground-fault leakage current detected, indicating moisture ingress or insulation breakdown.

02 // Non-Invasive Meter / Bench Verification

Inspect cord for cuts and verify switch box was not submerged. If dry switch box still trips GFCI, internal motor winding-to-ground leakage is indicated.

Platform / OEM Cross-Reference: Operating water temperature limit (115°F), 125°F submersible cutoff, LoSUDS 1 oz / 3 gal dosing, prohibition on granular detergents, daily air-drying, and monthly vinegar descaling apply across Bar Maid submersible models (AA-SUB, SS-100).

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
COR-125-AS GFCI Power Cord & Switch Assembly
Standard electrical ratings and plug type.
OEM ~$70–$120 est.
Part 2
oem replacement part
Isolated Match
SWT-196 Toggle Switch w/ Red Boot
Standard electrical ratings.
OEM ~$15–$25 est. / Generic ~$8–$15
Part 3
oem replacement part
Isolated Match
MTR-801 Submersible Motor (115V, 1/3 HP)
Proprietary submersible shaft/mounting.
OEM ~$341.24
Part 4
oem replacement part
Isolated Match
SWA-150 Switch & Box Assembly
Custom enclosure.
OEM ~$60.02
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified commercial bar glass washers submersible replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERFAULT IMPLICATED
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORNOMINAL ON SKU
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:Stainless Steel

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Do not use if any parts are cracked, broken or leaking oil. Immediately cease use if oil sheen/leak, cracked housing, or damaged cord insulation is observed. Never lay machine on its side for storage or drying. Keep switch box and cord out of water.

Root Failure Mechanism: GFCI Nuisance or Fault TrippingClick to spotlight part ↑

01 // Trigger ConditionSplash/immersion of external switch box, nicked power cord jacket, or moisture ingress past motor shaft seal.
02 // Degradation PhysicsCreates a ground-fault leakage current, causing the GFCI to trip for safety.
03 // Lockout / ImpactUnit loses power, interrupting operation; potential electrical shock hazard if GFCI fails.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Wash sink stays noticeably warm during continuous operation: The partially submerged sealed motor transfers heat from its stator windings directly into the surrounding wash-sink water, which helps maintain a warm wash temperature. This is an intended design feature. (True fault when: If the water becomes excessively hot (above 115°F) and triggers the thermal cutoff, or if the motor is excessively hot to the touch when removed from the water, it may indicate an underlying issue like seized bearings causing overcurrent.)

Other Bar Maid AA-SUB Diagnostic Sheets