Observed Condition: If moisture accumulates in the bottom chassis drip tray beneath both drawers and bridges the Active Flood Protection float sensor contacts, the control board shuts off the dual water inlet valve and commands continuous drain pump operation.
Immediate Non-Invasive Triage: Shut off water supply and isolate utility power; requires qualified technician inspection of internal tub seals, hose couplings, and bottom drip pan without bypassing the float switch.
Platform Cross-Reference: Core Architecture Heritage: The sliding double-drawer layout, motorized dynamic lowering lid seal, and integrated dual-function BLDC sump pumps share mechatronic design lineage with the Fisher & Paykel DishDrawer platform under Haier Group ownership.
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
WD24X30798 | OEM Drain Hose Extension Kit Mandatory OEM kit for remote sink plumbing installations exceeding factory drain hose length. |
Unlisted | |
| Part 2 accessory |
CXQD2H2PNFB | Café Flat Black Handle Kit for Double Drawer Dishwasher Exact-match OEM tubular handle kit engineered specifically for Café double drawer dishwashers. |
$399.00 | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified dishwashers replacements & cutout specs. |
Compare | See Top Replacements → |