UNIT DOWN? Verified OEM & Aftermarket Fix Kit Below
Jump to Parts Kit ↓
HARDWARE SYMPTOM MODEL: UH130B

Champion UH130B: Extended Cycle Time (Rinse Sentry Hold)

Observed Condition: Cycle stretches beyond 141 seconds (up to 4–5 minutes) before final rinse triggers.

Immediate Non-Invasive Triage: Measure incoming hot water supply temperature at the Y-strainer. If <110°F, the 70°F rise booster requires extra dwell time (Rinse Sentry working as designed). If supply is >= 120°F, clamp-meter all legs of Booster Element comp_04_booster_heater_element (~19–22A draw).

Platform Cross-Reference: Shares interchangeable debossed stainless wash/rinse arms (113521), control drawer architecture, and plumbing manifold layout with Champion UH230B and UL130.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
111235 Built-In Booster Immersion Heater (4.0 / 5.2 kW)
Must match voltage, wattage, material (Incoloy), and physical mounting (3-bolt flange).
$160–$230 (OEM)
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified commercial undercounter dishwashers replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Turn power switch OFF before performing any maintenance or service.
  • Do not use hydrochloric/muriatic acid or sodium hypochlorite bleach for deliming or sanitizing.

Root Mechanism: Booster Immersion Heater Scale Encrustation & Hi-Limit Trip

Trigger: Operation with hard water (>3-5 gpg) at high temperatures (185°F–195°F).

Physics / Degradation: Accelerated CaCO3 precipitation onto the Incoloy sheath; scale blocks heat dissipation into the water, causing internal sheath overheating and eventual element burnout.

System Lockout / Impact: `Rinse Sentry` stalls (extended cycles), element burnout (no sanitizing rinse), or hi-limit trip (machine shutdown).

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Cycle stretches beyond 141 seconds (up to 4–5 minutes) before final rinse triggers.: The 'Rinse Sentry' circuit is designed to hold the machine before the final rinse phase until the booster thermostat verifies >= 180°F. This is a safety interlock to ensure NSF sanitization, especially with incoming water below 110°F or during rapid back-to-back cycles. (True fault when: If incoming water supply is consistently >= 120°F and the cycle still extends excessively, it may indicate a fault with the booster heater element (comp_04_booster_heater_element) or its contactor (comp_08_booster_heater_magnetic_contactor).)

Other Champion UH130B Fault Signals