UNIT DOWN? Verified OEM & Aftermarket Fix Kit Below
Jump to Parts Kit ↓
HARDWARE SYMPTOM MODEL: CDC22P1BBB

COMFEE’ Countertop CDC22P1BBB: Ed

Observed Condition: Inter-Board Communication Failure

Immediate Non-Invasive Triage: Completely disables the front user interface. Check for broken wire or loose connector between main chassis PCB and door TFT/LED board.

Platform Cross-Reference: Electromechanical parts engineered for Midea's WQP6 platform (including heating element 17476000001509 and water inlet valve 17476000005962) are shared across sister models under the Midea, Farberware, and Danby brands . Do not infer that user-interface logic, button mappings, or exterior fascia panels are universally interchangeable.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
17476000001509 Tubular Heating Element
OEM part number confirmed compatible with CDC22P1BBB. Verify voltage (120V) prior to installation.
$39.99
Part 2
oem replacement part
17476000005962 Solenoid Water Inlet Valve
OEM part number confirmed compatible with CDC22P1BBB. Ensure 3/4" male threaded inlet fitting.
$9.95
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified countertop compact automatic dishwasher replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Root Mechanism: Inter-Board Door Harness Fracture leading to Ed Error

Trigger: Mechanical flexure across repetitive door open/close cycles

Physics / Degradation: Multi-conductor copper harness experiences cyclic metal fatigue at the bottom hinge pivot, severing communication lines to the front control panel.

System Lockout / Impact: Completely disables the front user interface; displays 'Ed' communication code.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Operating Noise Level up to 52 dB: 49 dBA represents the steady-state acoustic sound power during primary wash circulation; 52 dBA represents operational peak sound pressure during drain pump ejection and high-velocity spray arm start-up. (True fault when: Persistent, unusually loud grinding, rattling, or squealing noises beyond normal operational peaks may indicate a fault.)
False-Alarm Check — Slight standing water in the sump bottom after a cycle: The sump normally retains a slight water seal to prevent odors and keep pump seals lubricated. (True fault when: Excessive water pooling (more than a slight film) or foul-smelling stagnant water indicates a drainage blockage or pump issue.)

Other COMFEE’ Countertop CDC22P1BBB Fault Signals