UNIT DOWN? Verified OEM & Aftermarket Fix Kit Below
Jump to Parts Kit ↓
EXPLICIT FAULT CODE MODEL: CDC17P0AWB

COMFEE' CDC17P0AWB: E3

Observed Condition: Heating element malfunction

Immediate Non-Invasive Triage: Unplug unit and test heater resistance and NTC thermistor continuity; note that Rapid (rinse) and Fruit cycles are unheated by design.

Platform Cross-Reference: Shares core 5L Midea CDC17P0 wet-end, heater, thermistor, and error-code architecture with CDC17P0AWW and CDC17P0ABB; does not share the 6L tank, auto-open latch, or UV light of CDC17P2AWW.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
17476000007943 Heating Element
Exact fit for CDC17P0AWB and shared across CDC17P0/CDC17P2 series.
~$25–$45 OEM est.
Part 2
oem replacement part
17176000012008 Temperature Sensor (NTC Thermistor)
Exact OEM part number (Pos 48) confirmed by Midea Encompass.
$5.95 OEM
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified dishwasher countertop portable replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • The manual provides warnings regarding electrical shock (unplug before service), water damage (E4 protocol), and freeze damage (forced drainage). It does not explicitly prohibit opening the outer shell for component access, but implies professional service for internal parts.

Root Mechanism: Heating Circuit Fault (E3)

Trigger: Mineral scale buildup on heating element, electrical transient, or component aging.

Physics / Degradation: Scale-induced thermal fatigue of the heating element, failure of the NTC temperature sensor, or malfunction of the heater relay on the main PCB.

System Lockout / Impact: Dishwasher fails to heat water, resulting in cold wash cycles and ineffective cleaning, triggering an E3 error code.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Wet Plastics After Cycle: The CDC17P0AWB has a sealed manual-latch door and a polymer tub, which retains less drying heat than stainless steel. This design traps high-humidity vapor, leading to condensation on plastic items if the door is not manually opened. (True fault when: If the Air Refresh fan is not operating, or if excessive moisture remains even after manually cracking the door open for an extended period.)

Other COMFEE' CDC17P0AWB Fault Signals