UNIT DOWN? Verified OEM & Aftermarket Fix Kit Below
Jump to Parts Kit ↓
EXPLICIT FAULT CODE MODEL: CDC22P2AWW

COMFEE’ CDC22P2AWW: E4

Observed Condition: Base Pan Overflow / Leak: Safety float seated in bottom chassis pan lifts and triggers microswitch, forcing continuous drain pump operation.

Immediate Non-Invasive Triage: Check for internal hose rupture, sump gasket failure, overfilling, or unlevel chassis.

Platform Cross-Reference: Sibling models CDC22P1ABB (all-black) and CDC22P1BWB (white/black) share the exact WQP6-3602H mechanical, hydraulic, and electrical platform under Midea America Corp distribution. Cosmetic door parts and color-coded trim panels must not be transferred to the target white SKU.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
12176000003496 Safety Float Overflow Switch
OEM part for CDC22P2AWW.
$12.00 - $22.00
Part 2
oem replacement part
12676000000820 Sump Sealing Ring Gasket
OEM part for CDC22P2AWW.
$8.50 - $14.00
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified compact countertop dishwasher replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Do not knock filters against sink walls (causes contortion and mesh tears).
  • Never operate dishwasher without filters installed.

Root Mechanism: Base Pan Leak Detection (E4 Error Trip)

Trigger: Sump gasket degradation, loose hose clamp, unlevel placement

Physics / Degradation: Water weeps past degraded sump O-ring into bottom chassis pan; polystyrene float lifts, tripping microswitch.

System Lockout / Impact: Dishwasher operation disabled, continuous drain pump operation.

Root Mechanism: Foam Overfill & Suds Lock

Trigger: Accidental introduction of liquid dish soap or rinse aid spill

Physics / Degradation: Manual soap generates high-volume foam; pump cavitates, wash pressure drops, and foam forces past door bottom into drip tray.

System Lockout / Impact: Tripping E4 error, standing dirty water.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Operating sound level between 49 dBA and 52 dBA.: Normal acoustic emission sits within the 49 to 52 dBA operating envelope depending on water pressure and countertop resonance. Sump base dampening pad is installed to attenuate pump resonance. (True fault when: Sudden, significantly louder, or abnormal grinding/whining noises could indicate a fault with the wash or drain pump.)

Other COMFEE’ CDC22P2AWW Fault Signals