Observed Condition: Triggered when the turbine flow meter fails to detect the calibrated pulse volume within 4 minutes of inlet valve opening. Caused by closed supply valve, inlet water pressure <6 PSI, kinked supply hose, or clogged inlet valve mesh screen.
Immediate Non-Invasive Triage: Verify water supply valve is open, check for kinked supply hose, clean inlet valve mesh screen, and ensure dynamic water pressure is above 6 PSI.
Platform Cross-Reference: Chassis, hydraulic sump, pump drive, and control electronics are identical across BIDW1802SS (Stainless), BIDW1802BL (Black), and BIDW1802WH (White) models.
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
universal Midea-style… | Water Inlet Solenoid Valve Must match 120V AC coil voltage and physical bracket orientation; do not substitute European 220V valves. |
~$35.00–$65.00 via authorized parts channels | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified undercounter compact dishwasher replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Silt/sediment in supply line or low dynamic municipal pressure.
Physics / Degradation: Sediment accumulation blinds the conical filter screen on valve inlet, causing incoming water flow rate to drop below flow meter detection threshold. Flow meter sends insufficient pulse train, and the 4-minute fill timer elapses.
System Lockout / Impact: Controller halts cycle with E1 code, preventing the appliance from washing.