Observed Condition: Drainage Failure: Kinked drain hose, blocked 3-stage filter, or discharge hose raised above maximum allowed head height.
Immediate Non-Invasive Triage: Inspect drain hose for kinks or blockages. Ensure drain hose is not elevated above the maximum allowed height. Clean the 3-stage sump filter assembly.
Platform Cross-Reference: DW001-5 / ZX-DW-01 is a related prior-generation platform; do not transfer its 6-cycle program list or chassis wiring schematics to the 8-cycle DW002-5A.
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
59-inch flexible… | Corrugated Drain Hose Must maintain internal diameter matching the rear barbed discharge port. |
~$10–$15 (Marketplace average) | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified countertop portable dishwasher replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Pinched discharge hose, high hose loop, or sump blockage.
Physics / Degradation: Drain pump generates low static head. If hose is kinked or elevated beyond allowable height, pump times out before sump sensor clears.
System Lockout / Impact: Cycle halts with dirty water pooled in tub; displays E2. Requires manual hose inspection and pump flush.