FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
EQUIPMENT DOWN? Interactive Bench Isolation & Verified OEM Fix Kit Below
Jump to Fix Kit ↓
HARDWARE SYMPTOM MODEL: DSP3 TIER 1–2 BENCH DIY

Eurodib DSP3: Tank stays dry or overflows continuously

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

The wash tank either fails to fill with water or continuously fills beyond the normal operating level, leading to overflow.

02 // Non-Invasive Meter / Bench Verification

Check 3/4 in G water supply. Verify solenoid coil voltage (comp_06) and clear the pressure-switch air trap tube (comp_07).

Platform / OEM Cross-Reference: Sibling DSP3DPS shares core 208 V chassis/pump/rinse architecture while adding an integrated drain pump.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
300025 Water Inlet Solenoid Valve
Verify 140 °F+ hot-water diaphragm rating.
OEM: ~$55–$95 / Generic: ~$25–$45
Part 2
oem replacement part
Isolated Match
300026 Water Level Pressure Switch
Must match OEM specifications for accurate water level sensing.
OEM: ~$35–$65
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified commercial high temp undercounter glasswasher replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERFAULT IMPLICATED
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMFAULT IMPLICATED
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:PTFEPolypropyleneStainless SteelStainless-SteelVITON

Failure Physics & Causal Isolation

Root Failure Mechanism: Water Inlet Solenoid or Level Switch MalfunctionClick to spotlight part ↑

01 // Trigger ConditionScale or sediment accumulation within the solenoid valve (comp_06) or grease/debris fouling the air trap of the water level pressure switch (comp_07).
02 // Degradation PhysicsSolenoid valve jams open or closed, or the pressure switch fails to accurately detect water level.
03 // Lockout / ImpactMachine fails to fill with water (no-fill) or continuously fills and overflows (overfill).

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Wash cycle appears longer than 2 minutes.: The Thermocontrol feature ensures proper thermal sanitization by holding the cycle until the rinse water reaches the specified temperature. This is a safety and performance feature, not a fault, if incoming water is cold. (True fault when: If the cycle consistently extends despite adequate hot water supply (131–140 °F) and no other issues, it could indicate a failing heating element (comp_02), relay (comp_08), or thermostat (comp_04, comp_05).)

Other Eurodib DSP3 Diagnostic Sheets