EXPLICIT FAULT CODE MODEL: DD24DCHTX9 N

Fisher & Paykel DD24DCHTX9 N: Error Code E5

Observed Condition: Lid Actuator Stall: Indicates the motorized lid failed to close or open correctly.

Immediate Non-Invasive Triage: Check for dishware obstructing lid closure; inspect actuator yoke links for derailment.

Platform Cross-Reference: Diagnostic error code architecture (A-series operational codes, F-series critical fault codes, E-series optical service diagnostics) is shared across all Generation 9 / Series 7 DishDrawers.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
522085 Dual Lid Actuator Kit (2-Pack)
OEM part number ensures direct fitment and proper operation of the motorized drop-lid mechanism.
~$130–$142 USD
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified built in dual drawer dishwasher replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Field technicians are instructed to conduct formal earth continuity and electrical insulation resistance testing before repowering the appliance following any heater or motor replacement.
  • Strictly prohibited: table salt, sea salt, rock salt, or detergent pods in salt port for water softener.

Root Mechanism: Drop-Lid Seal Bypass / Actuator Link Wear

Trigger: Actuator gear wear, yoke derailment, or dish overloading (tall dishware pressing upward against drop lid).

Physics / Degradation: The silicone perimeter gasket fails to compress completely, or the actuator mechanism slips.

System Lockout / Impact: Wash spray escapes into the chassis, potentially causing F1 errors or damage to internal components.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Undissolved Detergent Tablets: Short or low-water cycles may fail to dissolve dense compacted powder tablets in the dispenser. (True fault when: If tablets consistently remain undissolved even on longer, hotter cycles, or if the dispenser mechanism is physically blocked.)
False-Alarm Check — Standing Condensation on Tub Flange: Fan-assisted drying leaves residual moisture along the cool top perimeter flange, which can transfer to user clothing upon opening. This is a characteristic of active condensation drying. (True fault when: If water is actively dripping from the lid seal during a wash cycle, or if the base pan flood sensor is triggered.)

Other Fisher & Paykel DD24DCHTX9 N Fault Signals