UNIT DOWN? Verified OEM & Aftermarket Fix Kit Below
Jump to Parts Kit ↓
EXPLICIT FAULT CODE MODEL: DD24DCTX9N

Fisher & Paykel DD24DCTX9N: Error Code F2

Observed Condition: Motor Not Rotating

Immediate Non-Invasive Triage: Inspect rotor sump for foreign debris; check spray arm for free rotation.

Platform Cross-Reference: Drawer slide mechanics: Heavy-duty steel ball-bearing runners carry a factory-rated 77-pound dynamic load per drawer pair

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
524285P Motor Rotor Assembly
Includes permanent magnet rotor and wash/drain dual impellers; verify tight clearance in stator well.
~$85 – $115
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified dual drawer dishwasher replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Removing the direct-drive stator assembly from the base of the polypropylene tub requires an OEM bayonet spanner wrench (tool P/N 525826) to torque the composite locking ring nut. Disassembly by non-certified personnel poses severe risks of improperly seating the large-diameter elastomer O-ring, which will result in high-volume water leakage directly into the lower electronics enclosure.
  • Replacing the wash controller PCB (P/N 518490P) requires programming the board's phase and tub orientation parameters (upper master versus lower slave) via diagnostic keystrokes; unconfigured replacement boards will fail to execute wash cycles.

Root Mechanism: Foreign Object Rotor Sump Seizure

Trigger: Hard debris (broken glass fragments, toothpicks, fruit seeds) bypassing mesh filter

Physics / Degradation: Debris drops through the coarse filter plate and wedges between the high-speed permanent magnet rotor sleeve and the stator well wall; BLDC motor stalls on startup.

System Lockout / Impact: BLDC motor stalls, triggering diagnostic code F2. Halts wash cycle; requires user disassembly of spray arm, filter plate, and manual rotor extraction.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Varying acoustic noise levels (42 dBA vs 44 dBA): 42 dBA is the acoustic emission of the tall top drawer running standard cycles; 44 dBA is the maximum operational acoustic envelope during simultaneous dual-drawer heavy wash cycles. Both are within specified operating parameters. (True fault when: If noise levels exceed 44 dBA during any cycle, or if new, unusual grinding/clunking sounds are present.)

Other Fisher & Paykel DD24DCTX9N Fault Signals