EXPLICIT FAULT CODE MODEL: DD24DHTI9 N

Fisher & Paykel DD24DHTI9 N: F2 Fault Code

Observed Condition: SmartDrive Rotor Jamming: Broken glass shards, fruit seeds, or toothpicks bypass filter and jam rotor.

Immediate Non-Invasive Triage: Remove rotor from sump well and inspect for foreign objects.

Platform Cross-Reference: Core drive mechanics, direct-drive brushless motors, planar heater plates, motorized lid actuators, and error reporting protocols are shared across the Phase 9 platform (DD24 and DD60 families).

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
524922P SmartDrive Motor Rotor Assembly
Rotor generation must match Phase 7–9 housing; incompatible with Phase 5.
~$40–$65
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified built in dishwashing equipment replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • The outer chassis panels are permanently joined via mechanical clinching; structurally deformed frames cannot be disassembled or straightened and require complete chassis replacement.
  • The ion-exchange resin tank within the water softener assembly is a hermetically welded plastic cartridge that cannot be serviced or repacked; resin contamination mandates complete module replacement.

Root Mechanism: Rotor Impeller Obstruction & Boss Wear

Trigger: Ingestion of hard foreign debris (bone chips, glass shards, fruit seeds).

Physics / Degradation: Debris bypasses the filter, settles into the sump well, jamming the rotor and generating F2/E5 motor faults. Prolonged jamming can cause friction and melt the rotor boss.

System Lockout / Impact: Wash cycle interruption, F2/E5 error codes, potential damage to motor rotor.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Knock-to-Pause Sensitivity Irregularities: Overly heavy or improperly braced custom cabinetry panels can dampen the vibration transmission to the piezoelectric sensor, reducing its sensitivity. (True fault when: If the feature is entirely unresponsive with a correctly installed, lightweight panel, or if other control functions are also erratic.)

Other Fisher & Paykel DD24DHTI9 N Fault Signals