Fisher & Paykel DD24DT4NX9: Water Pooling / Drain Failure (Fault A3 / F1 / F2)
What this means: Occurs when tub water level fails to drop during drain interval; debris wedged under rotor is the primary cause. F2 is also associated with rotor jams.
60-Second Verification Check
Check for visible debris in the sump area after removing the filter plate and spray arm.
Verified Replacement Parts
SmartDrive Motor Rotor Assembly
Must verify serial revision; Series 9 units use 524922P rotor. Ensure central locknut is torqued correctly.
Why This Happens & Safety Warnings
- Do not bore out spray arm nozzles with metal picks or drills.
- Allow filter plate to cool after cycle completion before handling.
What triggers it: Ingestion of hard foreign debris (glass shards, olive pits, toothpicks)
What wears out inside: Debris drops past the edge of the filter plate into the open sump cavity, wedging between the rotating permanent magnet rotor blades and the plastic pump housing.
Symptom on machine: The motor stalls, throwing an F2 code and leaving standing dirty wash water in the tub.
Cross-Compatible Platforms: Lid Actuator Mechanisms: Actuator kit 522085 / SFP988 and perimeter lip gasket 529964P represent shared platform parts across 24-inch double DishDrawers.