UNIT DOWN? Verified OEM & Aftermarket Fix Kit Below
Jump to Parts Kit ↓
EXPLICIT FAULT CODE MODEL: DD24SCTX9

Fisher & Paykel DD24SCTX9: Alert Code A3 (Drawer Cannot Drain / Standing Water)

Observed Condition: Water level fails to drop within the calibrated timeout window.

Immediate Non-Invasive Triage: Check cylindrical drain filter for blockage; inspect drain hose for kinks.

Platform Cross-Reference: Diagnostic error codes ('A' user alerts and 'F' technical fault codes) and the four-level service diagnostic sequence are shared across the Fisher & Paykel DD24/DD60 platform.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
524922P SmartDrive™ Motor Rotor Assembly
Fits Fisher & Paykel DishDrawer models ending in revision suffix 8 or 9; incompatible with earlier Series 603 units without locknut updates.
$89.99 OEM / ~$44.00 Third-Party
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified single drawer dishwasher replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Do not allow residual water to stand in unheated dwellings subject to freezing temperatures. Freezing water expands and cracks the polymer pump volute and splits the water inlet valve body. (Source: 4)

Root Mechanism: Sump Rotor Impeller Jam from Solid Debris

Trigger: Small hard food debris (lemon seeds, toothpicks, glass shards)

Physics / Degradation: If the cylindrical drain filter is unseated or improperly locked, particulate debris passes into the sump volute, mechanically wedging between the impeller and housing.

System Lockout / Impact: Halts cycle with alert A3; requires disassembling the tub floor and manually extracting foreign debris from the rotor.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Wi-Fi Remote Control Inactivity Timeout: Under factory safety protocols, Remote Mode automatically disengages after 72 hours of inactivity or if the drawer is opened. This is a safety feature, not a malfunction. (True fault when: If Remote Mode cannot be engaged or disengages immediately after activation, it may indicate a fault with the Wi-Fi module or control board.)
False-Alarm Check — Acoustic Sound Emission (42 dBA vs 44 dBA): The acoustic profile was reduced from 44 dBA to 42 dBA in current build 82336 due to firmware modulation of the BLDC motor. Both are normal for their respective production builds. (True fault when: If the unit suddenly becomes significantly louder than its rated dBA, it could indicate a mechanical issue with the motor or pump.)

Other Fisher & Paykel DD24SCTX9 Fault Signals