FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: DishDrawer 522657 TIER 1–2 BENCH DIY

Fisher & Paykel DishDrawer 522657: Flash Rust Staining on Stainless Steel Cutlery and Silverware

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Superficial orange/brown iron oxide deposits appearing on stainless steel knives, forks, and spoons after a wash cycle.

02 // Non-Invasive Meter / Bench Verification

Inspect all coated wire rack modules (522657, 512818, 524868) for breached PA11 coating where exposed carbon steel is shedding free iron ions into the wash water.

Platform / OEM Cross-Reference: Racking architecture spans Single Drawer (e.g., DD60SAX9), Double Drawer (e.g., DD24DAX9), and Tall Tub (e.g., DD24STX6I1) models across DD60 and DD24 platforms.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
512818 Adjustable Folding Crockery Insert (F&P Crockery Insert FD 7PS)
Proprietary OEM geometry with integrated front/back clips for kinematic folding actuation; verify compatibility with specific DishDrawer generation (Phase vs. Series).
$20 - $55 USD
Part 2
oem replacement part
Isolated Match
522657 Primary Base Rack Grid Assembly
Proprietary OEM Rilsan PA11 coated carbon-steel structural wire foundation; must match DD60 (600mm) or DD24 (24-inch) tub width and generation mounting points.
$65 - $80 USD
Part 3
oem replacement part
Isolated Match
524867 Small Plate / Trapdoor Insert (Comb/Trapdoor or Plate Holder Kit BB)
Proprietary OEM secondary tine assembly for narrower vessel spacing.
$37 - $56 USD
Part 4
accessory
Isolated Match
Dishwasher Zinc/Magnesium… Aftermarket Dishwasher Zinc / Magnesium Sacrificial Anode
Speculative category accessory placed in the cutlery basket to attract circulating free iron ions and reduce flash rust deposition on stainless steel flatware.
$15 - $25 USD
Part 5
accessory
Isolated Match
523326 Combined Knife Clip Assembly
Proprietary OEM clip snapping directly onto the wire grid to restrain sharp blades during wash cycles.
$5 - $11 USD
Part 6
universal aftermarket part
Isolated Match
Liquid Vinyl / Silicone… Aftermarket Liquid Vinyl / Silicone Rack Repair Compound (e.g., ReRack)
Independent bench reference stopgap only: requires sanding rust to bare metal and alcohol cleaning, but non-crosslinked vinyl adhesive bonds inevitably degrade in pH > 10 alkaline wash water and 20°C–70°C+ thermal cycling.
$10 - $15 USD
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified dishwasher internal racking and structural mechanics replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERFAULT IMPLICATED
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMFAULT IMPLICATED
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:BLDCCarbon SteelCarbon-SteelPA11RilsanSiliconeStainless Steel

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Load sharp knives and utensils facing downward for user safety, or secure them in the Knife Clip (523326), while ensuring they do not project through the base rack mesh to obstruct the lower wash arm.
  • Do not load plates taller than 280mm (11.0 inches) in Standard Tubs or 310mm (12.25 inches) in Tall Tubs to avoid obstructing the descending motorized lid sealing diaphragm.

Root Failure Mechanism: Rilsan PA11 Coating Breach, Galvanic Oxidation, and Self-Accelerating Creeping RustClick to spotlight part ↑

01 // Trigger ConditionSharp cutlery blades, cast iron, or unglazed ceramic edges mechanically nick or abrade the 250-500µm Rilsan PA11 polymer coating during loading/unloading or wash agitation.
02 // Degradation PhysicsHighly alkaline wash water (pH greater than 10) penetrates the coating breach and acts as an electrolyte on the bare carbon-steel wire core. Rapid galvanic oxidation forms iron oxide (rust), which expands volumetrically and combines with differential thermal cycling shear (20°C to 70°C+) to mechanically peel back surrounding intact PA11 coating in a self-accelerating loop.
03 // Lockout / ImpactProgressive structural degradation of wire tines/grid, flaking polymer debris in the wash tub, and exposed rusting steel requiring modular replacement of the affected insert (512818, 524868) or base rack (522657).

Root Failure Mechanism: Collateral Flash Rust Deposition on Stainless Steel Cutlery from Exposed Rack CoreClick to spotlight part ↑

01 // Trigger ConditionOperating the DishDrawer while the Base Rack Grid (522657) or wire inserts (512818, 524868) have an unsealed breach in the PA11 coating exposing the carbon-steel core.
02 // Degradation PhysicsHigh-velocity, high-temperature (up to 70°C+), alkaline (pH > 10) wash water strips free iron ions from the oxidizing carbon-steel rack wire and galvanically deposits them onto stainless steel cutlery and silverware during the wash and rinse cycles.
03 // Lockout / ImpactCosmetic and surface corrosion (flash rust) staining expensive stainless steel flatware until the rusted rack module is replaced.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — A Double DishDrawer displays a U4 fault code and disables power on a drawer whose racking, loading clearance, and tub are completely normal.: U4 is an intentional safety interlock generated by the master/slave controller to disable the healthy drawer whenever the opposite drawer experiences a critical fault (such as a flood switch activation). (True fault when: Indicates an active fault condition in the opposite drawer rather than the drawer displaying U4.)
False-Alarm Check — The DishDrawer refuses to seal and halts the wash cycle with a U2 error when loaded with tall dinner plates or platters.: The DishDrawer uses a vertically compressed sliding tub with strict Z-axis clearance boundaries (280mm in Standard Tubs, 310mm in Tall Tubs). Halting with U2 when plates exceed these heights is normal protective behavior preventing lid diaphragm damage and water leaks. (True fault when: Only indicates a hardware fault if U2 persists when the rack is empty or loaded strictly below the 280mm / 310mm vertical boundary and seated properly.)

Other Fisher & Paykel DishDrawer 522657 Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...