Observed Condition: Electromechanical timers or electronic control modules pause cycle progression indefinitely during a water-heating hold phase while waiting for wash water to reach target temperature.
Immediate Non-Invasive Triage: Verify continuity of the high-limit thermostat (0.0 ohms cold) and calrod heating element (15–20 ohms), and inspect the P8 control board connector and thermistor if heating components test good.
Platform Cross-Reference: Replaces OEM cross-reference numbers 12758, 154290201, 154290202, 154290203, AP2109201, PS420575, and EAP420575 across Electrolux Home Products dishwashers (Frigidaire, Kenmore, Gibson, Kelvinator, Tappan, White-Westinghouse, Crosley).
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
154290204 | OEM Electrolux / Frigidaire High-Limit Thermostat Genuine factory OEM replacement with verified L200-100F calibration and UL File E19279 / CSA LR77886 platform recognition across Frigidaire, Electrolux, Kenmore, Gibson, Kelvinator, Tappan, White-Westinghouse, and Crosley dishwashers. |
~$41.03 to $64.78 | |
| Part 2 universal aftermarket part |
B09P8BCG6V | Aftermarket Compatible High-Limit Thermostat Dimensional and functional drop-in aftermarket replacement for OEM 154290204 distributed by UBNA Distribution LLC; supplied as bare switch without retainer clip or screw. Exact factory origin, UL/CSA markings, and calibration tolerance dispersion are unverified. |
~$10.00 to $18.44 | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified dishwasher high limit thermostat replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Cumulative thermal cycling and repeated 10–12 A switching events over the service life of the dishwasher.
Physics / Degradation: Electrical arc erosion/pitting of internal contact rivets or mechanical snap fatigue of the bimetallic disc prevents the contacts from closing or conducting current at room ambient (~70°F).
System Lockout / Impact: Series 120 VAC path to the calrod heating element remains permanently open (infinity / OL), resulting in unheated wash water, undissolved detergent, mid-cycle timer hangs during water-heating holds, and failure to dry dishes.
Trigger: Repeated wash/sanitize/dry thermal cycles or wider initial metallurgical tolerances on unbranded aftermarket production batches.
Physics / Degradation: Crystalline mechanical fatigue in the bonded bimetallic laminate shifts the snap-action trip threshold downward (e.g., <140°F instead of 200°F ± 5°F), causing the disc to open during normal operating temperatures.
System Lockout / Impact: Intermittent heating interruption before target wash or dry temperatures are achieved, causing erratic drying performance and extended heating hold durations.