Observed Condition: Water Inlet Timeout: Occurs if the internal pressure switch or flow counter fails to register proper water fill within firmware timeout.
Immediate Non-Invasive Triage: Check for partially closed stop valves, sediment in the inlet screen, or supply pressure below 5.8 psi.
Platform Cross-Reference: Scope: Specifications apply directly to the HDS18* base family, including HDS18B (Black), HDS18W (White), and HDS18SS (Stainless).
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
120V / 60Hz single… | Water Inlet Solenoid Valve Bracket screw pitch and electrical spade terminals must align with chassis frame. |
~$18.00–$32.00 | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified dishwashers replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Mineral sediment binding diaphragm or coil thermal fatigue.
Physics / Degradation: Particulate sediment in municipal water bypasses the screen or settles in the pilot chamber, preventing proper valve operation or triggering E1 timeout.
System Lockout / Impact: Machine halts cycle and beeps; no water fills the tub.