Observed Condition: Heating & Sensor Faults
Immediate Non-Invasive Triage: F8 indicates failure to achieve target temp; F6 indicates open/shorted temperature sensor circuit. Check heating element and thermistor connections.
Platform Cross-Reference: Hardware platform is shared across Kenmore 263.1462#, 263.1463#, 263.1464#, and 263.1467# series.
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
1100W, 120V immersion… | 1100W Calrod Heating Element Inspect rubber sealing washers; overtightening brass nuts can deform tub. |
~$40–$75 | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified built in undercounter dishwasher replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Heavy calcium carbonate scale build-up in hard water
Physics / Degradation: Mineral scale forms an insulative jacket over the sheath, causing internal resistance wire to overheat and melt.
System Lockout / Impact: Water not heated, dishes not dried, sanitization cycle fails.