UNIT DOWN? Verified OEM & Aftermarket Fix Kit Below
Jump to Parts Kit ↓
EXPLICIT FAULT CODE MODEL: TDQR01

NOVETE TDQR01: E6 / E5 Error

Observed Condition: Water Heating Failure (E6 is heating plate connection per manufacturer support; E5 is heating failure per manual)

Immediate Non-Invasive Triage: Unit halts mid-wash when water fails to heat; requires disc replacement or checking terminal looseness.

Platform Cross-Reference: Hardware is manufactured by Guangdong Jienuo Electric Appliances Co., Ltd. on the TDQR01 platform.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
120 V / 850 W circular… Sump Heating Disc Plate
The original perimeter silicone gasket must be carefully transferred during replacement.
$20–$30
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified portable countertop dishwasher replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Internal repairs require completely disconnecting the 120 V AC line cord and draining all residual water from the system.
  • Removing the bottom pan while connected to mains power exposes uninsulated high-voltage AC terminals on the power supply, heating element, and motor relays, presenting a severe risk of electric shock.

Root Mechanism: Sump Heating Disc Failure (E6 / E5 Error)

Trigger: Regular use in hard water areas or prolonged operation

Physics / Degradation: Mineral scale insulates the element face, driving internal coil temperatures beyond design limits until an open circuit forms.

System Lockout / Impact: Mid-cycle aborts, cold wash water, dishes not cleaned effectively.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Persistent Water Shortage Alarm: Trapped air pockets after dry storage prevent water from flowing from the reservoir into the pump volute. (True fault when: If the issue persists after performing the air purge procedure (shaking the unit), there may be a fault with the reservoir fluid level sensor or pump.)

Other NOVETE TDQR01 Fault Signals