Samsung DW80B7070US: 4C (Water supply trouble)
⚡ Bench Triage & Meter Telemetry
20–120 psi
01 // Observed Condition
Dishwasher detects insufficient water supply or fill rate.
02 // Non-Invasive Meter / Bench Verification
Verify 20–120 psi supply pressure and open shutoff valve; test inlet valve solenoid coil continuity.
Platform / OEM Cross-Reference: Shares DW7000B chassis, manual (DD68-00243A-00), and core mechanical/hydraulic BOM with DW80B7070UG/AA, DW80B7070AP/AA, DW80B7071US/AA, and DW80B6060US/AA.