Observed Condition: Keypad Stuck / Touch Lockout
Immediate Non-Invasive Triage: Console displays alphanumeric code E9. Liquid spills across the top door rim or condensation from opening the door mid-cycle can create a continuous conductive moisture film across touch points, simulating a stuck button.
Platform Cross-Reference: The error code matrix (E1, E4, E8, E9) is shared across Sharp's broader SDW family (including models SDW6747GS and SDW6757ES).
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
Main Control Circuit Board | Main Control Circuit Board Requires matching model suffix; holds master appliance executive firmware. |
~$120.00 – $180.00 | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified built in dishwasher replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Steam leakage, high ambient humidity, or liquid spills on the top control panel
Physics / Degradation: Condensing steam from opening the door mid-cycle creates a conductive moisture layer across top touch buttons, triggering the stuck-button fault (>30s).
System Lockout / Impact: Temporarily disables the control interface.