Observed Condition: Overflow / internal water leakage detected in the bottom chassis drip pan by the polystyrene float switch. Highest priority fault (overrides E1 and E2) that locks out wash cycles and forces continuous drain pump operation.
Immediate Non-Invasive Triage: Immediately shut off the kitchen faucet water supply and disconnect AC power. Check inside the tub for excessive suds caused by improper dish soap or spilled rinse aid, and inspect the door perimeter gasket for leaks.
Platform Cross-Reference: Operating hydraulic line pressure range of 0.04 to 1.0 MPa (5.8 to 145 psi) and recommended inlet hot water feed temperature of 120°F to 150°F (49°C to 66°C) apply across Sunpentown SD-series portable dishwashers.
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
30248 | Air Breather Siphon-Break Chamber Assembly Confirmed OEM side-wall polypropylene air breather assembly shared across Sunpentown SD-6501, SD-6502, and SD-6513 platforms. |
$36.75 | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified dishwashers replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Spilled liquid rinse aid / improper hand dish soap causing heavy suds, scale clogging the side-wall air breather chamber, or mechanical vibration/thermal aging loosening internal sump hose clamps and pump shaft seals.
Physics / Degradation: Water or surfactant foam overflows the air breather siphon break (Part 30248) or leaks past EPDM sump boots/pump seals into the stamped galvanized steel bottom drip pan, buoying the expanded polystyrene float switch.
System Lockout / Impact: Control board triggers highest-priority Error Code E4 (overriding E1/E2), locks out all user wash programs, and runs the synchronous drain pump continuously until the base pan is emptied and dried.