FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: BCW-70 TIER 4 LICENSED / SEALED

Thermolabel BCW-70: Adhesive Residue Transfer

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Gummy adhesive material remains on the test surface after the label is peeled off.

02 // Non-Invasive Meter / Bench Verification

Allow test item to cool completely before peeling the label. If residue occurs, use an appropriate adhesive remover or alcohol wipe for cleaning.

Platform / OEM Cross-Reference: 'Thermolabel' is a registered trademark of Paper Thermometer Co., Inc. (Manchester, NH, USA).

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
routine consumable
Isolated Match
BCW-70 Crystal Code BCW-70 10-Pack Temperature Labels
Direct replacement for ASIN B0G2R5Z8HH. Suitable for NSF 184 residential dishwashers and industrial equipment monitoring. Not compliant with FDA Food Code 4-703.11(B) for commercial food service.
~$2.80–$9.00 USD per 10-pk
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified temperature indicator labels replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALFAULT IMPLICATED
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:PolypropyleneStainless Steel

Failure Physics & Causal Isolation

Root Failure Mechanism: Adhesive Residue Transfer on TablewareClick to spotlight part ↑

01 // Trigger ConditionPeeling the label from hot dishware or equipment surface immediately after the thermal cycle (while surface temperature is >60°C).
02 // Degradation PhysicsElevated temperature lowers the cohesive strength of the acrylic polymer, causing the adhesive to shear and transfer residue to the substrate.
03 // Lockout / ImpactLeaves gummy residue on dining ware or equipment surfaces, requiring additional cleaning with solvents or degreasers.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Partial edge darkening or 'halo effect' on the indicator window.: The 'halo effect' is a normal thermodynamic behavior indicating that the surface reached the activation temperature (70°C / 158°F) but did not sustain it for the minimum required dwell time (10-15 seconds) to fully melt the chemical core. (True fault when: If the label consistently shows a halo effect despite verified adequate dwell times and proper application, it could indicate a manufacturing defect in the chemical core or barrier film, though this is less common than dwell time issues.)

Other Thermolabel BCW-70 Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...