Whirlpool W10348269: F9E1 / 9-1 (Drain Timeout Error)

Observed Condition: Host dishwasher control board flags F9E1 (or flashing 9-1) when the low-water float switch or drain monitoring circuit does not reset within the allotted drain period.

Immediate Non-Invasive Triage: Inspect sump cavity, volute throat, and external drain hose/check valve for debris clogs; measure stator DC resistance across the 2-pin terminal spades with a multimeter (normal: 15–19 Ohms nominal, 15–25 Ohms allowable; OL/infinite indicates open coil; less than 10 Ohms indicates short).

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
universal aftermarket part
B0CH3CC9GZ AMI PARTS Aftermarket Dishwasher Drain Pump Assembly (B0CH3CC9GZ / W10348269)
Form, fit, and functional aftermarket replacement for Whirlpool, Kenmore (665 series), Maytag (MDB series), KitchenAid, JennAir, Amana, and Estate undercounter dishwashers. Draws 50 W (vs. 35 W–45 W OEM); lacks verified standalone UL/CSA mark and unverified internal thermal fuse.
$18.00–$28.00
Part 2
oem replacement part
WPW10348269 Genuine Whirlpool OEM Dishwasher Drain Pump (Askoll M286 / M316 Platform)
Factory-certified OEM part featuring lower 35 W–45 W coil dissipation, OEM winding insulation, integrated thermal cut-out profile, and quieter bushing clearances.
$48.00–$74.00
Part 3
oem replacement part
8269144A Dishwasher Corrugated Drain Hose Assembly with Internal Check Valve
External host-appliance hydraulic component critical to inspect for check-valve clogs or kinks when diagnosing standing water or F9E1 errors.
$25.00–$52.00
Part 4
oem replacement part
W10872845 Dishwasher Sump Fine Filter Assembly
External host-appliance upstream filtration barrier replacing a torn or punctured filter is mandatory to prevent recurring foreign-object impeller jams in the replacement drain pump.
$27.00–$48.00
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified dishwasher drain pump assembly replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Disconnect electrical power at the circuit breaker or unplug the dishwasher before removing the toe-kick access panel or servicing the pump.
  • Evacuate standing water from the sump basin (using a wet/dry vacuum or sponge) and place a towel beneath the sump before twisting the pump counter-clockwise to prevent subfloor water spills.

Root Mechanism: Foreign Object Impeller Jamming and Synchronous Rotor Stall

Trigger: Hard culinary debris (broken glass shards, fruit seeds, bone splinters, toothpicks) bypasses an unlatched or punctured upstream sump filter (>2.0 mm cutoff).

Physics / Degradation: Foreign particulate wedges between the open symmetrical impeller vanes and the volute wall or strikes the spinning blades, mechanically locking the low-starting-torque permanent magnet rotor or chipping/eroding impeller blades.

System Lockout / Impact: Zero or severely reduced wastewater evacuation; dishwasher aborts cycle with standing water in the basin and flags F9E1 drain timeout.

Root Mechanism: Stator Winding Thermal Insulation Breakdown and Open/Short Circuit

Trigger: Sustained locked-rotor stall from an impeller jam, prolonged operation in hot wash water, or continuous 120 VAC energization beyond the 5-minute intermittent duty limit due to a stuck host control board relay.

Physics / Degradation: Stator coil draws continuous stall/load current in an unventilated dry cavity without fluid heat dissipation, causing rapid Joule heating that degrades the magnet wire enamel insulation or trips an internal thermal cut-out (if present).

System Lockout / Impact: Permanent electrical failure of the drain pump (open circuit OL or turn-to-turn short <10 Ohms), requiring unitary pump replacement.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Brief audible twitch, rattle, or oscillation chatter upon drain pump startup before settling into steady rotation.: Single-phase permanent magnet synchronous motors lack a dedicated starting direction pole; upon 60 Hz excitation, the two-pole magnet rotor oscillates rapidly against hydraulic resistance until electromagnetic phasing locks it into 3600 RPM clockwise or counter-clockwise rotation. (True fault when: Indicates a fault only if the pump fails to lock into synchronous rotation, continues humming/buzzing without evacuating water, or emits sustained loud grinding throughout the entire drain cycle.)
False-Alarm Check — Moderately louder 60 Hz hum or high-pitched whine during the active drain cycle compared to the factory Askoll OEM pump.: Aftermarket reproductions exhibit slightly looser rotor shaft bushing clearances in tooling and a higher 50 W electrical profile compared to the 35 W–45 W OEM baseline while still evacuating wastewater normally. (True fault when: Indicates a fault if accompanied by reduced water discharge flow, standing water after the cycle, active water leakage, or harsh metallic/glass grinding noises.)

Other Whirlpool W10348269 Fault Signals