BLACK+DECKER BR1640KB: Fresh-Food Compartment Too Warm While Freezer Stays Cold
What this means: Refrigerator compartment temperature exceeds 46°F while freezer holds near 0°F to -8°F.
60-Second Verification Check
Check rear freezer bulkhead for heavy frost buildup; verify electronic control is not locked on warmest setting (46°F) and freezer dial is not blocking airflow.
Verified Replacement Parts
Evaporator Fan Motor
Must match electrical and mechanical specifications to ensure proper airflow and system operation.
Defrost Thermal Fuse / Bi-Metal Thermostat
R600a units require ignition-protected (sealed) switches/thermostats for safety. Must match temperature ratings.
Why This Happens & Safety Warnings
- W Appliance Co. explicitly mandates that component parts of the hermetic R600a sealed refrigeration circuit be replaced with like components by factory-authorized service personnel to minimize ignition risk.
What triggers it: Normal operation, but with a fault in the defrost system or airflow.
What wears out inside: Defrost heater, thermal fuse, NTC sensor, or evaporator fan fails, causing the evaporator fins to pack with solid ice.
Symptom on machine: Airflow to the fresh-food compartment is choked off, leading to the fridge warming above 46°F while the freezer remains cold.
Cross-Compatible Platforms: BR1640KB (Black), BR1640KS (Stainless Look), and BR1640KW (White) share the exact BR1640K mechanical, thermal, and electrical platform