UNIT DOWN? Verified OEM & Aftermarket Fix Kit Below
Jump to Parts Kit ↓
EXPLICIT FAULT CODE MODEL: US

BODEGA US: E1, E2, E3, E4, E7, E8

Observed Condition: Brand-family controller fault codes indicating issues with sensors, display link, or fan/power stage.

Immediate Non-Invasive Triage: Disconnect power for 5 minutes to reset. If fault recurs, test NTC probe resistance and harness continuity before replacing main PCB.

Platform Cross-Reference: Electrical/refrigerant nameplate (146W, 1.4A, R600a 0.08 lbs, 215/50 Psig) and 35.24"H dimensions drawn from BODEGA's official 11.4 Cu.Ft 3-door LG-330HA documentation.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Sealed epoxy NTC… NTC Temperature Probe
Matching exact R25 curve and beta constant is mandatory to avoid display offset and control errors.
Generic: ~$8–$20
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified stainless worktop back bar coolers replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Unauthorized repairs or modifications void warranty.
  • Any sealed-system repair requires an EPA-certified technician trained in A3 flammable hydrocarbon recovery, nitrogen brazing, deep vacuum pull, and gram-scale recharging.

Root Mechanism: NTC Thermistor Drift or Open/Short Fault

Trigger: Moisture ingress into thermistor sheath or electrical fatigue.

Physics / Degradation: Resistance drift or open/short circuit, sending incorrect temperature signals to the main PCB.

System Lockout / Impact: Erratic temperature cycling, inaccurate display, or 'E' fault codes, leading to warm cabinet or excessive cooling.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Frequent water buildup on exterior glass doors and frame.: This is normal condensation physics when ambient dew point exceeds the glass surface temperature, especially in high-humidity commercial bar environments. (True fault when: Fault if moisture appears *inside* the double-pane glass cavity (indicating a failed IG seal) or if a gasket gap fails the dollar-bill pull test (indicating an air leak).)
False-Alarm Check — Soft humming and gentle gurgling sounds from the refrigeration system.: These are normal acoustic signatures of the R600a compressor operating and refrigerant phase change within the sealed system. (True fault when: Fault only if loud metallic rattling occurs (check leveling feet and cabinet contact against surrounding bar woodwork) or if the compressor runs continuously without cooling.)

Other BODEGA US Fault Signals