BODEGACOOLER BTC-580FC: HH (High Temperature Alarm)

Observed Condition: Cabinet temperature greater than 25°C (77°F) for more than 2 hours. Compressor stops.

Immediate Non-Invasive Triage: Check for ajar doors, blocked external vents (insufficient clearance), fouled condenser coil, or internal airflow obstruction.

Platform Cross-Reference: BTC-580FC shares identical IEC compliance filings, cabinet geometry, wiring topology, and fault logic with partner ODM BTC-580FC models (Yeego / VEVOR) and scales up from the 2-door BTC-350FC sibling.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
universal aftermarket part
10 kOhm or 5 kOhm NTC… NTC Temperature Sensor(s)
Requires matching resistance curve and physical form factor.
~$10–$25
Part 2
universal aftermarket part
115V/60Hz or DC brushless… Condenser / Evaporator Fan Motor
Requires matching voltage, current, physical dimensions, and airflow characteristics.
~$25–$65
Part 3
oem replacement part
115V/60Hz ~250W-class… Hermetic R290 Compressor (60 g charge)
Requires exact matching of refrigerant type, charge, electrical ratings, and cooling capacity. Installation requires R290 certification.
~$220–$400
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified commercial back bar cooler replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Any brazing on the R290 refrigeration system requires full recovery, oxygen-free nitrogen purging, system earthing prior to charging, and strict avoidance of overfilling.
  • Power cord must be replaced by manufacturer or service agent if damaged.

Root Mechanism: Back-Bar Thermal Trapping (HH Cutoff)

Trigger: Unit installed in a confined back-bar space with insufficient ventilation clearance.

Physics / Degradation: Poor heat rejection from the condenser coil due to recirculated hot air and potential dust buildup.

System Lockout / Impact: Cabinet temperature exceeds 25°C (77°F) for over 2 hours, triggering the 'HH' alarm and compressor shutdown, leading to warm beverages.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Compressor and fan hum/noise: The unit's compressor and dynamic fans produce a normal operating hum, rated at less than 55 dB, which is suitable for bar environments. (True fault when: Loud rattling, grinding, or unusually high-pitched noises may indicate an unlevel unit, loose components, or fan blade interference.)