Coolake C-335BH: Standing water on stainless floor

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Accumulation of water inside the refrigerated cabinet.

02 // Non-Invasive Meter / Bench Verification

Check cabinet level with spirit level; clear evaporator drain port of debris/biofilm.

Platform / OEM Cross-Reference: Deep technical specs (127 lbs weight, 115V Type B plug, 1.78 kWh/day, ETL/NSF ANSI 7, 88 lb shelf load) are cross-confirmed from the structurally identical stainless-exterior sibling C-335SH.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
Standard 115V… Digital Temperature Controller
Verify cutout dimensions, voltage, and NTC probe curve (e.g., 10kΩ @ 25°C) before bench substitution.
OEM: Covered 3 yrs / Generic: ~$35–$75
Part 2
oem replacement part
Isolated Match
Custom-welded dart-in or… Magnetic Door Gasket (×3)
Measure outside-to-outside (O.D.) dimensions and dart profile before ordering.
Generic/Custom: ~$40–$85 per door
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified commercial back bar refrigeration replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALFAULT IMPLICATED
MOD_04 // FLUID & WATERFAULT IMPLICATED
MOD_05 // AIRFLOW & ACOUSTICFAULT IMPLICATED
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMFAULT IMPLICATED
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:NTCPTCR290Stainless SteelStainless-Steel

Failure Physics & Causal Isolation

Root Failure Mechanism: Condensate Drain Clog & Cabinet PoolingClick to spotlight part ↑

01 // Trigger ConditionBar spills, airborne yeast/mold, or general debris accumulation in the drain system.
02 // Degradation PhysicsBiofilm or debris clogs the evaporator drain tube, preventing auto-defrost meltwater from reaching the evaporation pan.
03 // Lockout / ImpactMeltwater backs up, pooling on the interior stainless floor, potentially leading to odors, unsanitary conditions, or water damage.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Noticeable compressor/fan hum during active pull-down, settling into steady white noise.: This is normal operational physics for a reciprocating compressor and forced-air fans during active cooling cycles, especially after initial startup or frequent door openings. (True fault when: Metallic rattling, rapid click-off cycling (overload tripping), or screeching fan bearings.)