UNIT DOWN? Verified OEM & Aftermarket Fix Kit Below
Jump to Parts Kit ↓
HARDWARE SYMPTOM MODEL: GRMC2273CD

Frigidaire GRMC2273CD: SY CE / SY EF

Observed Condition: Communication Error (SY CE) / Evaporator Fan Fault (SY EF)

Immediate Non-Invasive Triage:

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
5304519115 PC Board Filter / Control Board
No generic equivalent; exact Electrolux/Frigidaire firmware required. Compatibility depends on exact cabinet suffix (00/01/02).
OEM: ~$20–$90 (varies by board rev)
Part 2
oem replacement part
5304529587 Crisper Drawer Cover Assembly
Model-specific molded frame & glass support. Compatibility depends on exact cabinet suffix.
OEM: ~$60–$110
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified french door 4 door refrigerators counter depth external dispenser convertible middle drawer replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • R600a (Isobutane) is a flammable hydrocarbon refrigerant; requires hydrocarbon-rated recovery and non-brazing mechanical repair protocols by EPA/R600a-certified technicians.
  • Damage from unauthenticated/counterfeit water filters is excluded from warranty.

Root Mechanism: Dispenser UI / Main Board Communication Fault

Trigger: Repeated door flexing, power surges, or general electrical stress.

Physics / Degradation: Disruption of the internal serial communication bus between the dispenser UI and the main control board.

System Lockout / Impact: Erratic dispenser panel behavior, including beeping, flashing, or crashing, leading to loss of control or display functionality.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Audible beeping when door ajar or after power loss: Doors ajar <=5" self-close due to Auto-Close cam hinges. Wider openings trigger the Door Ajar Alarm. A Power Failure Alarm sounds after power interruptions. (True fault when: If doors do not self-close when ajar <=5", or if alarms persist after acknowledging and verifying door closure/power restoration, it may indicate a fault with the door hinges, sensors, or control board.)

Other Frigidaire GRMC2273CD Fault Signals