What this means: Internal temperature is above the freezing point, or food items are not frozen solid.
60-Second Verification Check
Check thermostat setting, ensure door is fully closed and gasket is sealing, check for excessive frost buildup, ensure adequate ventilation around condenser.
Verified Replacement Parts
Removable Wire Shelf
Must fit internal dimensions and be food-safe.
Ice Cube Tray
Must be food-safe and fit within freezer dimensions.
Why This Happens & Safety Warnings
- Do not attempt to repair or replace any part of your appliance unless it is specifically recommended in this manual. All other servicing should be referred to a qualified technician.
- Danger – Risk of Fire or Explosion. Flammable Refrigerant Used. To Be Repaired Only By Trained Service Personnel. Do Not Puncture Refrigerant Tubing.
What triggers it: Manufacturing defect (poor weld/joint), material fatigue, corrosion, or physical damage to refrigeration lines.
What wears out inside: Loss of R600a refrigerant charge, leading to insufficient heat transfer.
Symptom on machine: Inability to maintain freezing temperatures, complete loss of cooling function.
What triggers it: Mechanical wear, contact degradation, or sensing bulb failure.
What wears out inside: Inaccurate temperature sensing or failure to switch compressor on/off.
Symptom on machine: Freezer runs continuously (over-cooling/excessive frost) or does not run at all (inadequate cooling/thawing).