Symptom Guide Model: ICE-23R

ICECASA ICE-23R: Rattling, humming, or scraping noise

What this means: Unusual mechanical sounds emanating from the unit.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Periodic cooling pause every 4 hours — This is normal operation: the automatic electric defrost system activates every 4 hours to clear frost from the evaporator coil.

Level unit on casters, inspect condenser/evaporator fan clearance, tighten loose fasteners.

2

Verified Replacement Parts

#1 Most Likely Fix ~$35–$85 (est. category range)

Evaporator / Condenser Fan Motor

115V 60Hz commercial… Copy Part #

Requires matching electrical specifications, physical dimensions, and rotation direction for safe and effective operation.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in commercial reach in refrigerator replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
  • Manual specifies only qualified technicians should perform electrical/internal repairs.
  • R290 is an ASHRAE A3 flammable hydrocarbon refrigerant; sealed-system work requires EPA Section 608 / hydrocarbon-certified refrigeration technicians using spark-free recovery and nitrogen purging.
Evaporator/Condenser Fan Motor Bearing Wear

What triggers it: Continuous commercial duty, exposure to airborne grease, dust, and humidity.

What wears out inside: Bearings in the fan motors experience drag, wear, or seize due to contamination or fatigue.

Symptom on machine: Increased noise, reduced airflow, loss of cooling efficiency (evaporator fan), or reduced heat rejection (condenser fan), leading to compressor stress.

Cross-Compatible Platforms: ICECASA reach-in series (ICE-23R, ICE-36R, ICE-49R, ICE-81R) shares the CAREL controller architecture, 4-hour auto-defrost logic, and 2-year/6-year warranty structure

Other ICECASA ICE-23R Problems (4)
1. Quick Test 2. See Fix Parts ↓

Type any brand, model number, error code, or part number...