HARDWARE SYMPTOM MODEL: ITR-48 TIER 1–2 BENCH DIY

ICECASA ITR-48: Water on floor inside or outside cabinet

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Presence of water pooling inside the cabinet or on the kitchen floor around the unit.

02 // Non-Invasive Meter / Bench Verification

Clear condensate drain line; verify doors close flush (<90° auto-close) with no gasket gap.

Platform / OEM Cross-Reference: Shares the ITR worktop platform (30"D × 35.6"H, R290 NUT35NR compressor, CAREL-family digital controller, 33°F–41°F range) with ITR-27 and ITR-60.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
Custom-cut magnetic… Magnetic Door Gasket (×2)
Must match original dimensions and magnetic profile for proper seal.
Check Live Stock
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified stainless worktop back bar coolers replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERFAULT IMPLICATED
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORNOMINAL ON SKU
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:NTCR290Stainless SteelStainless-Steel

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • R290 (Propane Hydrocarbon) is an A3 flammable refrigerant; requires spark-free recovery/service tools and strict leak-free brazing/charging. Only EPA Section 608 / R290-certified hydrocarbon refrigeration technicians should service the sealed system.
  • Disconnect power before any cleaning or maintenance.

Root Failure Mechanism: Condensate Drain Clog Leading to Water LeakageClick to spotlight part ↑

01 // Trigger ConditionNormal defrost cycle producing condensate water.
02 // Degradation PhysicsFood debris, slime, or biofilm accumulates in the condensate drain line, blocking the flow of defrost water.
03 // Lockout / ImpactDefrost water overflows the drain pan, leading to water pooling inside the cabinet or leaking onto the kitchen floor, creating a slip hazard and potential property damage.

Root Failure Mechanism: Door Misalignment or Gasket Gap Leading to Warm Cabinet and CondensationClick to spotlight part ↑

01 // Trigger ConditionShipping damage, heavy commercial use (frequent opening/slamming), or improper installation.
02 // Degradation PhysicsDoor hinges become misaligned or magnetic gaskets lose their seal, creating gaps that allow warm, humid ambient air to infiltrate the cabinet.
03 // Lockout / ImpactIncreased energy consumption, frost buildup on the evaporator coil, condensation inside the cabinet, and elevated cabinet temperatures, potentially leading to food spoilage.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Slight temporary rise above setpoint every 4 hours: This is a normal and necessary part of the automatic electric defrost cycle, designed to melt frost buildup on the evaporator coil. (True fault when: If the temperature rise is excessive (e.g., above 50°F) or the cabinet does not recover to the setpoint range shortly after the defrost cycle ends.)
False-Alarm Check — Dark cabinet interior when doors open: The ICECASA ITR-48 model is designed without interior cabinet lighting. This is a design feature, not a fault. (True fault when: NOT_APPLICABLE (as there is no light to fail))