Kenmore 46-75475: Frost Buildup Behind Drawers / Floor Water
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
Frost behind freezer drawers or water pooling near cabinet base
02 // Non-Invasive Meter / Bench Verification
Verify swing door closes squarely without internal drawer interference; inspect drain trough for ice blockage.
Platform / OEM Cross-Reference: Shares exact 15.1 cu. ft. / 427 L Vestel chassis, inverter cooling system, and 72-page manual with 46-75472 (White) and 46-75479 (Black).