Do not attempt to repair the sealed refrigeration system unless EPA 608 certified and trained in flammable hydrocarbon refrigerants.
Unplug the unit before any cleaning or maintenance.
Before Ordering Parts: Normal Operation vs. True Fault
False-Alarm Check — Compressor running with a humming or buzzing sound.: The unit's acoustic rating is 51-55 dB, which is normal for a commercial merchandiser. The compressor will cycle on and off to maintain temperature. (True fault when: If the noise is significantly louder than 55 dB, includes rattling or grinding, or the compressor runs continuously without cooling.)
False-Alarm Check — Brief periods of warmer temperatures or dripping water inside the cabinet.: The unit features automatic defrost. During this cycle, the evaporator coil warms to melt frost, and the water drains to the self-evaporation tray. (True fault when: If defrost water overflows the tray, or if the cabinet temperature remains elevated after the defrost cycle.)