KoolMore SCDC-6P-SSL: Audible clicking every few minutes, compressor hot
What this means: Compressor repeatedly turning on and off in short intervals, often accompanied by a hot compressor shell.
60-Second Verification Check
Check condenser cleanliness and wall outlet voltage (115V ±10%) before condemning compressor or start relay.
Verified Replacement Parts
Condenser Fan Motor
Must match wattage, RPM, rotation, and shaft/mount.
1/10 HP R-600a Compressor
Requires certified A3 hydrocarbon technician for installation. Must match voltage, frequency, HP, and refrigerant type.
Why This Happens & Safety Warnings
- Servicing of the R-600a sealed system requires an EPA Section 608 / A3 hydrocarbon-certified refrigeration technician with spark-proof tools and precision scale charging.
- Prior authorization from KoolMore is required for any warranty service.
What triggers it: Unit operating in a commercial kitchen environment (e.g., near fryers/grills)
What wears out inside: Kitchen grease and dust accumulate on condenser fins and intake louvers, blocking airflow. This leads to increased head pressure in the refrigeration system, causing the compressor to overheat and trip its thermal overload protector.
Symptom on machine: Unit stops cooling, food temperatures rise, potential damage to compressor.
Cross-Compatible Platforms: Koolmore Supply Inc. 1-year commercial-only warranty, pre-authorization rule, and indoor ambient/sunlight exclusions apply across the commercial refrigeration line.