FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
EQUIPMENT DOWN? Interactive Bench Isolation & Verified OEM Fix Kit Below
Jump to Fix Kit ↓
HARDWARE SYMPTOM MODEL: MFI2269VEQ1 TIER 1–2 BENCH DIY

Maytag MFI2269VEQ1: Rhythmic clicking from lower rear machine compartment accompanied by loss of cooling

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Bi-metallic thermal overload protector inside start device WPW10197428 repeatedly tripping and resetting under high locked-rotor amperage when the compressor fails to start.

02 // Non-Invasive Meter / Bench Verification

Confirm dedicated 115V AC outlet voltage and verify lower condenser airflow is unobstructed before referring to a qualified technician for external relay/capacitor inspection.

Platform / OEM Cross-Reference: The diagnostic logic and capacitor vulnerabilities of the Jazz Board (WPW10310240) apply across the broader Maytag/Amana/Whirlpool French-door family.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
WPW10197428 Compressor PTC Start Device (Relay and Overload)
Confirmed OEM starter for compressor W10160407; dossier cautions that low-cost generic starters may use lower-grade Barium Titanate prone to earlier thermal fracture.
$40 - $60 (OEM) / $10 - $15 (Generic)
Part 2
oem replacement part
Isolated Match
WPW10662129 Compressor Motor Run Capacitor
Confirmed SKU electrical rating and terminal piggyback fitment onto WPW10197428; any bench equivalent must meet or exceed 250VAC continuous motor-run safety rating.
$45 - $60 (OEM) / $15 - $25 (Generic)
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified french door bottom freezer refrigerator replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALFAULT IMPLICATED
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICFAULT IMPLICATED
MOD_06 // OPTICAL & SENSORNOMINAL ON SKU
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSActivated CarbonCopperEPDMNTCPTCSilicone

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • End-user tampering with the R-134a hermetic vapor-compression loop is prohibited; sealed-system work requires EPA Section 608 certification, vacuum pump recovery, and torch brazing.
  • Drilling, puncturing, or cutting into the polyurethane-foamed cabinet walls or interior liner is strictly prohibited due to permanently encapsulated wiring harnesses and static condenser capillary loops.

Root Failure Mechanism: Compressor PTC Start Relay Ceramic Disc Fracture and No-Cool Overload ClickingClick to spotlight part ↑

01 // Trigger ConditionCumulative compressor start-up cycles accelerated by AC line brownouts, brief power interruptions, or elevated head pressure from fouled condenser coils.
02 // Degradation PhysicsRepeated high inductive inrush heating fractures or crumbles the Barium Titanate (BaTiO3) PTC thermistor disc inside WPW10197428, preventing start-winding engagement; the stalled compressor draws locked-rotor amperage and repeatedly trips the bi-metal thermal overload.
03 // Lockout / ImpactComplete loss of vapor-compression cooling in both fresh-food and freezer compartments with risk of food spoilage until the external start device is replaced.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Hissing, sizzling, or popping sounds emanating from behind the lower rear freezer wall during compressor off-cycles.: During pre-emptive adaptive defrost cycles, frost melting off the single finned evaporator drips onto the energized electric calrod defrost heater and rapidly vaporizes. (True fault when: Indicates a fault only if accompanied by persistent freezer warming, error states, burning insulation odor, or meltwater overflowing onto the freezer floor due to a blocked drain.)
False-Alarm Check — Compressor running for substantially longer durations than older legacy refrigerators.: High-efficiency Energy Star refrigeration systems are engineered to run longer, steadier duty cycles to minimize start-up energy spikes and maintain tight cabinet temperature stability. (True fault when: Indicates a fault or maintenance issue if compartment temperatures rise above setpoint, frost blankets the rear freezer panel, perimeter gaskets are torn, or lower condenser coils are matted with lint/pet hair.)