Observed Condition: Cabinet rises above -10°F; compressor runs hot or cycles on thermal overload.
Immediate Non-Invasive Triage: Inspect condenser coil behind front louver; verify condenser fan rotation; check suction/head pressures if coil is clean.
Platform Cross-Reference: True's 7-7-7 Hydrocarbon warranty, reversing condenser fan motor (RCU) dust-clearing cycle, and T-Series installation/electrical compliance rules apply across the True T-Series -HC family.
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
945035 | Evaporator Fan Blade (115V) Confirm rotation & diameter via serial number. |
OEM ~$25–$55 | |
| Part 2 oem replacement part |
960276 | Condenser Fan Blade Match to OEM specification. |
OEM ~$30–$60 | |
| Part 3 oem replacement part |
983911 | Hermetic R290 Compressor Always verify exact 115V/60Hz R290 compressor P/N by True serial number. Required for warranty/A3 compliance. |
OEM ~$650–$1,100 | |
| Part 4 oem replacement part |
851111 | Capillary Tube (R290) Match exact ID/length to unit serial PCN. Requires EPA-certified R290 technician. |
OEM ~$79 / Generic ~$15–$25 | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified commercial reach in foodservice freezer nsf 7 replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Normal operation in commercial kitchen environment
Physics / Degradation: Floor-level lint/grease coats condenser fins, reducing heat rejection. This leads to elevated head pressure and discharge temperature.
System Lockout / Impact: Compressor cycles on thermal overload, leading to reduced cooling performance, increased energy consumption, and eventually oil coking or winding failure of the compressor.
Trigger: Compressor overheat or moisture/debris ingress after prior sealed-system service.
Physics / Degradation: Wax, carbon, or other contaminants (oil coking) plug the first 1–2" of the small ID capillary tube, or the filter drier becomes restricted.
System Lockout / Impact: Starved evaporator, resulting in low suction pressure, poor cooling performance, and a warm cabinet. Can lead to eventual compressor failure.