EXPLICIT FAULT CODE MODEL: FS-251

Bosch FS-251: E18 / E29 (Drain Timeout)

Observed Condition: Water evacuation time exceeded normal threshold.

Immediate Non-Invasive Triage: Check lower coin trap for foreign objects or blockages.

Platform Cross-Reference: WGB24600UC / WQB245B0UC (500 Series White) share core chassis, drum volumes, R-290 refrigerant, and closet clearance engineering with 800 Series Pearl Steel WGB246AXUC / WQB245AXUC.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
universal aftermarket part
6205ZZ (25x52x15mm) &… Washer Drum Bearings
Standard industrial deep-groove ball bearing dimensions.
$10–$25
Part 2
oem replacement part
00425642 Bearing Water Seal
Exact dimensional and lip geometry match.
$15 (Third-Party) / $45 (OEM)
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified laundry systems replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Do not wash primary lint filters in high-temperature dishwashers.
  • Refrigeration loop contains flammable R-290; do not breach without certified non-sparking protocol compliance.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Dryer takes 2 to 3+ hours per load.: Heat pump dryers operate at lower temperatures (110°F to 130°F) to preserve fabrics and maximize efficiency, inherently requiring longer cycle times. (True fault when: When cycles extend past 4 hours or are accompanied by E01/E02 error codes indicating filter blockage.)

Other Bosch FS-251 Fault Signals