Chuancheng 9164761: F066 / 'Clean plinth filter' / 'Airways Blocked'
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
Host Miele T1 main logic board detects an abnormal thermal gradient or static pressure differential across the closed-loop airstream (governed by sensitivity parameter P20), flagging a severe airflow restriction.
02 // Non-Invasive Meter / Bench Verification
1. Inspect and clean the upstream primary door lint screens and check that any unused fragrance flacon port shutter is closed (since the sensor reads total path resistance). 2. Extract the plinth filter carrier and inspect the foam for dry lint loading, residual moisture from recent washing, or invisible hydrophobic fabric softener film. 3. Wash the foam with warm water (and mild detergent if fabric softener is used), squeeze flat without wringing, and air-dry 100% before testing.
Platform / OEM Cross-Reference: Universal applicability of Miele T1 maintenance rules: warm tap-water washing only (mild detergent only for oily residue), flat squeezing without wringing or twisting, mandatory 100% air-drying prior to reinstallation, and strict prohibition against running the dryer without the plinth filter installed.