What this means: Drum tumbles, but no heat is produced, or burner ignites once then fails to relight in subsequent cycles.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Brief click followed by soft burner ignition whoosh — This is the normal operational cycle of the gas valve solenoid opening and the atmospheric burner igniting, as the thermostat cycles the burner on/off to maintain temperature.

Observe igniter glow through peephole; if igniter glows and clicks off without flame, test gas valve coil resistance. Check for TCO trip.

2

Verified Replacement Parts

#1 Most Likely Fix ~$30–$65 OEM / ~$15–$25 Generic

Hot-Surface Igniter (HSI)

120V Silicon… Copy Part #

Must match OEM voltage, wattage, and physical dimensions for safe and effective ignition.

Option #2 • Secondary / Related Part ~$25–$45 OEM / ~$12–$20 Generic

Gas Valve Solenoid Coil Kit

279834 Copy Part #

Must match OEM electrical specifications and physical configuration for safe gas valve operation.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in clothes dryers replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
  • Unplug power and shut off gas valve before opening cabinet.
  • LP conversion requires qualified gas technician to install OEM LP orifice/regulator kit and leak-test.
Exhaust Restriction Leading to Thermal Cutoff (TCO) Open

What triggers it: Failure to clean lint screen or inspect exhaust duct; improper venting installation.

What wears out inside: Lint accumulation restricts airflow, causing the burner chamber and exhaust path to overheat. The single-use thermal cutoff (TCO) opens as a safety measure.

Symptom on machine: No heat production, extended drying times, potential fire hazard.

Gas Valve Solenoid Coil Thermal Drift/Failure

What triggers it: Repeated thermal cycling and electrical operation of solenoid coils.

What wears out inside: Solenoid windings degrade with heat and age, leading to increased resistance or intermittent operation. The valve may open on a cold start but fail to reopen after the first thermostat-controlled heat cycle.

Symptom on machine: Intermittent or complete loss of heat, extended drying times.