Observed Condition: The dryer stops prematurely, leaving clothes damp, despite using a sensor-based cycle.
Immediate Non-Invasive Triage: Clean sensor bars with rubbing alcohol; test on Timed Dry to isolate sensor vs. heat fault.
Platform Cross-Reference: Shares chassis/console family with electric sibling 2669162
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
Independent Bench… | Gas Valve Solenoid Coil Kit Must match voltage, coil configuration, and mounting for specific gas valve. Safety critical. |
OEM: $25–$45 / Generic: $12–$20 | |
| Part 2 oem replacement part |
Independent Bench… | Glow-Bar Igniter Must match voltage, physical dimensions, bracket, and electrical connector. Safety critical. |
OEM: $35–$65 / Generic: $15–$25 | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified clothes dryers gas replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Regular use of fabric softener sheets.
Physics / Degradation: Wax and silicone residue from fabric softener sheets coats the moisture sensor bars, creating an insulating layer that prevents accurate conductivity readings.
System Lockout / Impact: Smart Sensor Drying cycles terminate prematurely, leaving clothes damp. Requires manual intervention (Timed Dry) or sensor cleaning.